This inspection survey must be conducted by qualified QA/QC personnel with knowledge of the fireproofing system, and recommended and approved by Isolatek International. As a result, any damage to the fire protection system can be easily repaired in accordance with Isolatek International’s application instructions.Īn annual inspection program is recommended to ensure that the integrity of a completely installed fireproofing system is maintained. Tunnel walls may be subjected to vehicle impact. Routine annual inspections may be carried out on the Spray-Applied Fire Resistive Materials (SFRMs) to ensure that the product will continue to perform its intended function. Inspection and Repair Procedures of the CAFCO ® FENDOLITE ® M-II / ISOLATEK ® Type M-II and CAFCO FENDOLITE TG / ISOLATEK Type TG System for Tunnel Applications – Short Form Refer to our Application Techniques section for more details regarding the step by step processes used. plastic coated galvanized or stainless steel profile mesh) may then be installed prior to the application of CAFCO FENDOLITE M-II / ISOLATEK Type M-II.įor applications onto metal lath substrates, concrete surface cleaning and the application of an SBR keycoat is not normally required. The specified method of mesh retention (i.e. For heavily contaminated substrates, this may be accomplished by pressure washing the entire concrete surface with a minimum 3000 psi pressure washer.įor direct application to concrete surfaces, a CAFCO FENDOLITE M-II / ISOLATEK Type M-II / ISOLATEK SBR keycoat is applied to increase the surface area to be protected by CAFCO FENDOLITE M-II / ISOLATEK Type M-II.
![tunnelbear app tunnelbear app](https://www.savingyoudinero.com/wp-content/uploads/2014/05/TunnelBear.png)
Tunnelbear app free#
The substrate to be protected with the CAFCO ® FENDOLITE ® M-II / ISOLATEK ® Type M-II system must be prepared such that it is free from dirt, dust, oil, curing compounds, mold release agents or other contamination that would impair the adhesion of CAFCO FENDOLITE M-II / ISOLATEK Type M-II system. It is required that the substrates are prepared in accordance with Isolatek International’s written application instructions. Poorly prepared substrates will compromise the long term protection to the structure. diameter (13 mm).ĬAFCO FENDOLITE TG / ISOLATEK Type TG is mixed and then hand applied using common masonry tools.Ĭareful preparation of substrates is important. Correct preparation ensures that the durability of the fire protection system is maintained and the required level of adhesion is achieved.
![tunnelbear app tunnelbear app](https://downloadvpnfree.com/wp-content/uploads/2018/05/Download-VPN-free-Tunnel-Bear.png)
(25 mm) ID aluminum pole with a blow-off type nozzle cap, a nozzle orifice and valves for product and air control. The spray nozzle assembly must consist of a minimum 1 in.Screw-on type quick connect/disconnect couplings that do not restrict product flow are required.
![tunnelbear app tunnelbear app](https://venturebeat.com/wp-content/uploads/2015/05/Screenshot_2015-05-11-15-43-21.png)
(227 liters) capacity or larger, capable of operating speeds of 35 to 40 RPM. A paddle or ribbon-type mortar mixer with a safety cover, rubber tipped blades and provision for quick dumping of mix directly into the pump hopper is recommended.(420 L/min) and a minimum pressure of 50 psi (3.51 kg/cm²). Compressed air is required and must be delivered to the spray nozzle at a minimum volume of 15 cfm.A rotor stator type, open throat, screw feed pump with minimum “No.In order to obtain optimal results, the following spray equipment setup for CAFCO ® FENDOLITE ® M-II / ISOLATEK ® Type M-II on Industrial, Chemical and Petrochemical processing sites is required: